Optical Instrument
HomeOptical FiltersOptical InstrumentsNewsAbout Us

Home > Optical Instruments >Photocatalyst Illuminator

Xenon Light Source Application
Photocatalytic Illuminator


Xenon Light Source Application Photocatalyst Illuminator   The powerful cold UV light excites and accelerates the photocatalytic reaction!

  • Built-in mirror module effectively eliminates most of heat.
  • Embedded filter wheel enables to select any desirable wavelength
    (UV - VIS).
  • Continuous light control from 5 to 100 (Transmittance).
  • Uniform illumination is available.
  • Bright monochromatic light by our narrow bandpass filter.

  • PDF brochurepdf



System configuration example

Component

  • Xenon light source MAX-303
  • Light guide
  • Collimator lens (x0.5, x1.0, x2.0)
  • Mirror module (UV, VIS, UV-VIS)
  • Narrow bandpass filter


Output Intensity
10mW/cm2(290nm)
*Measuring Condition
   Collimator Lens x 0.5
Component


Comparative Verification

Light absorbance of TiO2
and "conventional" light sources
Light absorbance of TiO2
and "MAX-303" + bandpass filter
Light absorbance of TiO2  and "conventional" light sources
Light absorbance of TiO2 and "MAX-302" + bandpass filter


Optional Accessories

Mirror Module

Mirror Module Please use UV-type mirror module in case you use oxidized titanium in UV-activity, and please use VIS-type or UV-VIS-type mirror module in case you use VIS-activity.
Type
Wavelength
UV
250-385nm
VIS
385-740nm
UV-VIS
300-600nm
Spectral Performance
Spectral Performance

Light Guide

Light Guide The illuminating light from the MAX-303 is delivered to the point of use by the light guide efficiently. Dual branch light guide is available as well for your different needs.
Spectral Performance-Light Guide
 
Spectral Performance-Light Guide
Fused Silica Guide
  • Core Dia:200 um
  • Numerical Aperture:0.22
  • OperatingTemp:<500degC

  • Hybrid Guide
  • Core Dia:50 um
  • Numerical Aperture:0.57
  • OperatingTemp:<350degC

  • Optical Filters

    Optical Filters We prepare the optimized narrow bandpass filters for MAX-303. You can select monochromatic light with high transmission if the spectrum through Mirror Module is wide and insufficient. Especially it is useful for Photochromism, Photocatalyst and Chemical Analysis in UV range.
    XHQA300

    Collimator Lens

    Collimator Lens Collimator lens reduces the divergence of light from the light guide and provide uniform light output. It is suitable for directional backlighting which requires clear silhouette of an object.

    News

    Coming Events

    219th AAS Meeting
    Austin, TX USA
    9-12 January 2012
    Booth No: 215
    219th AAS Meeting
    Photonics West 2012
    San Francisco, CA USA
    24-26 January 2012
    Booth No: 2625

    Photonics West 2012
    go to top page